Leave Your Message

GTXGN-12V Type Solid Insulated Switchgear

● GTXGN-12V solid insulated switchgear adopts modular structure design to realize any combination and expansion of switchgear cabinet for easy maintenance and maintenance. Fully insulated, fully sealed, maintenance free, all live parts are fully insulated. Fully insulated busbars are used for longitudinal arrangement, which is convenient and reliable. It has an independent low- voltage room, which can be equipped with computer protection and various meters. It does not need to install a low-voltage chamber on the top of the cabinet to make the switch cabinets more beautiful and compact. It has an independent low-voltage room, which can be equipped with computer protection and various meters. It does not need to install a low-voltage chamber on the top of the cabinet to make the switch cabinets more beautiful and compact.

● Implement the GB3906 national standard.

    Project Name Unit Product Category
    Load Switch Combination Switch Breaker Isolation Switch
    Rated voltage kV 12 12 12 12
    Arc-extinguishing type - Vacuum Vacuum Vacuum -
    Rated current A 630 125 630 630
    Rated frequency Hz 50 50 50 50
    Main circuit resistance mQ W150 <500 Note 1 W150 W150
    Im in the power frequency withstand voltage is the same, relative to ground/break kV 42/48 42/48 42/48 42/48
    The lightning impulse withstand voltage is the same, relative to ground/break kV 75/85 75/85 75/85 75/85
    Rated short-circuit breaking current kA - 315  Note 2 20 -
    Rated short-circuit opening current kA 50 80  Note 2 50 -
    Rated short-time withstand current kA/s 20/4 - 20/4 -
    Rated peak withstand current kA 50 80  Note 2 50 -
    Rated cable charging breaking current A 10 - - -
    5% rated active load breaking current A 315 - - -
    Transfer current A - 3150 - -
    Average closing speed m/s 09 ±0.2 -
    Average opening speed m/s 13 ±0.2 -
    The opening and closing of the switch are not at the same time m/s W2 -
    Closing time m/s 25-60 -
    Opening time ms 17-45 -
    Closing bounce time ms W2 -
    Mechanical life Time Load switch/circuit breaker: 10,000; Isolation and grounding switch :3000
    Protection grade   IP67
    Partial discharge value Pc Note 1

    Note 1 in the above table: Use a conductive rod instead of a high-voltage fuse; Note 2: Press the high-voltage fuse; Note 3: All epoxy insulators

    Really should any of these items be of interest to you, please let us know.  We will be pleased to give you a quotation upon receipt of one's detailed specifications.  We've our personal specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future.  Welcome to take a look at our organization.

    Leave Your Message